Alarm Lists
Alarm
Over Temperature Warning
Over Temperature
Power On Self Test Failure
+12V A Failed
+12V B Failed
Real Time Clock
NTP Server Response Timeout
Internal Hardware Issue
Host Build Version Mismatch
System Clock Not Locked
Chassis Identity Not
Programmed
Selected Mux SCR Source is not
present
Host Identity Not Programmed
Uncontrolled release
No identity license
TS NIT is not valid
Unsupported Option Card
E-6
Description
Failure to take action may cause
permanent damage to the unit.
Please check the fans are working
correctly, and that the ambient
temperature is not excessive.
Failure to take action may cause
permanent damage to the unit.
Please switch off and refer to
Customer Support.
At least one start-up test has failed.
Problems amy be experienced with
the normal operation of the unit.
+12V A rail has failed. Please check
supply or contact Customer Support.
+12V B rail has failed. Please check
supply or contact Customer Support.
The Real-time clock has failed. The
time/date will not be stored between
power-ups.
The unit could not contact the NTP
Server. The time/date will drift over
time.
An Internal Hardware Issue has
occured. The system may not
function properly.
Host software is not at an officially
released version. Host function may
not be affected.
The system 27 MHz VCXO is not
locked. Check if the Mux SCR
Source is valid.
The chassis identity of the host
could not be read correctly.
Selected Mux SCR Source could not
be detected. Check if the Sync Card
is plugged in.
The host identity could not be read
correctly.
This combination of host and option
card software is not officially
supported. This may lead to
unexpected behavior.
This unit has not been licensed with
an identity.
At one or more TS the Send
extended NIT (SIRG) parameter is
switched On, and one or more of the
parameters Operator, Longitude or
Latitude have invalid values.
The Option Card in Slot 1 is not
supported with this software release.
This may lead to unexpected
behaviour.
Port Number
Alarm ID
0
00000442
0
00000443
0
00000444
0
00000445
0
00000446
0
00000447
0
00000448
0
00000449
0
0000044A
0
0000044B
0
0000044C
0
0000044D
0
0000044E
0
0000044F
0
00000450
0
00000680
o
00000451
Source
Severity
Base Unit
minor
Base Unit
critical
Base Unit
minor
Base Unit
warning
Base Unit
warning
Base Unit
minor
Base Unit
warning
Base Unit
minor
Base Unit
minor
Base Unit
minor
Base Unit
minor
Base Unit
minor
Base Unit
major
Base Unit
minor
Base Unit
critical
Base Unit
major
Base Unit
major