Web GUI Control
Parameter
SMPTE 2016
AFD Sustain
AFD Sustain Timeout
AFD Action on Reserved
Codes
Closed Captions
Closed Captions Source
Timecode
TC Mode
TC External Source
TC Dropframes
Broadcaster ID
Reception Timeout
Insertion Timeout
Broadcaster ID Mode
Default Servicename
Broadcaster ID Source
Broadcaster ID
Generic ANC
Generic ANC Extraction
Max ANC Bit Rate
5-112
Values
Off, On
Indefinitely, Default after Timeout, Off after
Timeout
0 to 5,10, 20, 50, 100, 120
Pass Through, Code as 0000
Off, VBI lines, SMPTE334
Off, External, Zero on Loss, External,
Freewheel on Loss, Internal
Auto, ANC VITC1, ANC VITC2, ANC LTC, VBI
Off, On, Auto
Off, Auto, Default Only, Source Only
No, Input, Default
Off, On
100 to 2000 kbps
Description
Controls whether SMPTE 2016 data can be used as a
source for AR info.
Control what AFD code goes out when AFD is lost at input.
Indefinitely: Maintains previously received AFD code
indefinitely.
Default after Timeout: Maintains previously received AFD
code for period specified in Sustain Timeout, then drop to
default, i.e. code 1000.
Off after Timeout: Maintains previously received AFD code
for period specified in Sustain Timeout, then switch AFD
off.
Control how long previous AFD code is maintained. Zero
means drop to default immediately on loss.
Specify what code is passed to the output when reserved
AFD codes are received at the input.
Pass Through: Passes code through unchanged.
Code as 0000: Changes code to 0000.
The source for Closed Captions data encoded as part of
the Video Stream. Only applicable when frame rate is
29.97 Hz.
Controls what mode the Time code (TC) is working in,
either Off, external source or internally generated. Also
sets what happens on loss of external source (zero or
freewheel).
Controls the external source of Time Code. Auto will select
the first source present in order of the drop down list.
Only in 525 line operation controls if Time Code takes
account of drop frames or not. Auto configures to external
source, or to ON for internal source.
Timeout in seconds for reception of Source ID from input
(RP207).
Timeout in seconds for insertion of default source ID.
Gives what to insert as a broadcaster ID.
The default service name to be used.
Indicates if the Broadcaster ID is derived from the input,
the default or is invalid.
The Broadcaster ID that is currently being inserted into the
output stream.
Controls whether Generic ANC is extracted from the SDI
stream or not as per SMPTE 2038-2008.
The maximum data rate of the Generic ANC data output.