Front Panel Control
FPGA Temperature
PHY0 Temperature
PHY1 Temperature
Mux SCR Source
Status of Service
Change State
IP Input system Compensation
What to Do on Reboot
TS Source IP Redundancy
BISS Mode
BISS Injected ID (14 hex digits)
BISS Keys table
UTC Time
UTC Date
SNTP Server
Reflex Version
DPI TCP Port
Alarm Status
4-26
FPGA Warning Temperature
FPGA Over Temperature
FPGA Temperature
PHY0 Warning Temperature
PHY0 Over Temperature
PHY0 Temperature
PHY1 Warning Temperature
PHY1 Over Temperature
PHY1 Temperature
1
The temperature in degrees centigrade of the host FPGA at which the
unit issues a warning.
The temperature in degrees centigrade of the host FPGA at which the
unit issues a critical alarm.
The current temperature in degrees centigrade of the host FPGA.
The temperature in degrees centigrade of the Ethernet PHY0 at which
the unit issues a warning.
The temperature in degrees centigrade of the Ethernet PHY0 at which
the unit issues a critical alarm.
The current temperature in degrees centigrade of Ethernet PHY0.
The temperature in degrees centigrade of the Ethernet PHY1 at which
the unit issues a warning.
The temperature in degrees centigrade of the Ethernet PHY1 at which
the unit issues a critical alarm.
The current temperature in degrees centigrade of the Ethernet PHY1.
Internal, Video. The source of the system clock reference used for
timing.
The Setmode state of the unit.
Changes the Setmode state of the unit. The available options depend
on the settings in Advanced/System/Base Unit/MGP Support/MGP
Mode.
0 – 5000 ms
Restore, Offline. Determines whether the streams remain offline after
reboot or their Setmode state is to be restored.
Non-Transparent, Transparent
BISS Security option (Normal or Advanced)
BISS injected ID used for transmitting the Encrypted Session Word
used for BISS-E encoding.
Table locations for BISS key storage and selection
The UTC time set on the unit.
The UTC date set on the unit.
The IP address of a time server in the network.
Selects the Reflex version to use for statistical multiplexing. Not
supported in the current release.
The port for the SCTE104 Slice messages to be transmitted.
The overall alarm status of the unit. The same as indicated by the light
pipe on the front panel.
EN/LZT 790 0023/1 R16A