Getting Started
Ethernet Control Port Parameters
A single IP port is defined for all Ethernet control traffic to and from the chassis. The
physical ports used for Ethernet control are by default the control Ethernet ports.
The control ports can raise an alarm during abnormal operational conditions.
The parameters defining the control Ethernet port are as shown in the following
table.
Table 3.2
Ethernet Control Port Parameters
Parameter
Values
Network Mode
Same Network [default]
Different Network
IP Redundancy Mode
Active-Active
Active-Standby [default]
Autorevert
Auto-revert to Primary
[default]
Auto-revert to Secondary
Autorevert delay
Active Interface
Primary, Secondary
Line Speed
Auto [default]
100 Mbps
1 Gbps
Duplex Mode
Auto [default]
Full Duplex
Half Duplex
Default MAC Address
aa:bb:cc:dd:ee:ff
IP Address
aaa.bbb.ccc.ddd
Subnet Mask
0.0.0.0 [default]
aaa.bbb.ccc.ddd
Default Gateway
0.0.0.0 [default]
aaa.bbb.ccc.ddd
IGMP mode selection
IGMP v3
3-10
Description
The interface pair is on the same
subnet.
The interface pair is on different
subnet.
The same traffic is present on both
interfaces all the time.
The secondary interface is active
only if the primary is down.
Defines which of the interface group.
will be used when connection is lost
The delay in seconds before a
redundancy switch occurs, after the
interface link is up. If this is set to 0
then switching happens immediately.
The currently active interface
The connection speed
Auto negotiate the mode
Simultaneously transmit and receive
Transmit and receive in a time
division manner
The virtual MAC address of the Gex
interface.
Virtual IP address of the control
interface group
Subnet mask for the control interface
group
No defined gateway
Gateway address for packets
outside the defined subnet
Uses version 3 of the IGMP protocol
Comments
Read only parameter
Read only parameter.
Read only parameter
Read only parameter
IP address used for control and
configuration of the unit.
Should not be set to 0.0.0.0