Control Interface Group
Network Mode
IP Redundancy Mode
Index
Autorevert
Autorevert Delay
Active Interface
Line Speed
Duplex Mode
Default MAC Address
IP Address
Subnet Mask
Gateway Address
Physical Control Interface <n>
Data Interface Group <n>
Network Mode
EN/LZT 790 0023/1 R16A
Port Type
Direction
Index
Default MAC Address
Link Status
Link Up Time
TX Packets
RX Packets
IP Address
unit with the same IP address within the network by sending out ARP
messages.
Same-Network, Different-Network. Read only parameter for the
control interface, and is set to Same-Network.
Active-Active, Active-Standby. Describes how the spare interfaces will
behave. For the control port, it is set to Active-Standby and is read
only.
Identifier of the interface group. Read only parameter.
Auto-revert to Primary, Auto-revert to Secondary. Shown only if the IP
Redundancy mode is set to Active-Standby. Determines what to do
when connection is lost.
The delay in seconds before automatic redundancy switching takes
place. Shown only if the IP Redundancy mode is set to Active-
Standby.
Read only parameter. Displays which interface is active. In Active -
Active redundancy mode both interfaces are active.
Auto, 100 Mbps, 1 Gbps. The transmission speed of the link.
Auto, Full Duplex, Half Duplex. Determines whether data should be
transmitted and received in a time divided manner (Half Duplex) or
transmission and reception can happen at the same time over the
same link (Full Duplex). Auto is for automatic configuration.
Virtual MAC address assigned to the Control Interface Group.
The IP address associated with the interface group.
The subnet mask associated with the interface group.
The gateway address associated with the interface group.
The physical data interface labelled as Ge <n> of the current control
interface group.
Ethernet. Read only parameter.
Output. Read only parameter.
Identifier of the physical data interface. Read only parameter.
The hardware address of the Ge <n> interface.
Link Down, Link Up. The status of the current physical data interface.
The time in days, hours, minutes and seconds the link is established.
Read only parameter.
The packets transmitted since the link is up.
The packets received since the link is up.
The IP address of the physical data interface.
Same-Network, Different-Network. If set to Different-Network, the two
ports in the group can belong to different subnets. In Different-Network
mode only the Active-Active Redundancy mode is supported.