Ericsson AVP 1000 Reference Manual page 466

Table of Contents

Advertisement

Alarm Lists
Alarm
VBI ANC334 closed captions not
detected on input
VBI WSS not detected on input
VITC not detected on input
Selected Time code source not
detected
ANC Bar not detected on input
OP-47 not detected on input
Max ANC Data Rate Exceeded
VPS not detected on input
Video 1 Encode Invalid
Configuration
Advanced Parameters
Reflex PCR Exchange Timeout
Reflex SetRate Msg Timeout
Reflex Apply-Time out of range
E-10
Description
Unable to find closed caption data
on any of the configured lines.
Please check the video input. For
more details on the type of VBI, see
the VBI status page.
Unable to find WSS (ETSI or AFD)
data on any of the configured lines.
Please check the video input. For
more details on the type of VBI, see
the VBI status page.
Unable to find VITC data on any of
the configured lines. Please check
the video input. For more details on
the type of VBI, see the VBI status
page.
For the selected Time code source
no Time code was found. If in auto
mode no source was found on any
input. Make sure that the correct
source is configured.
ANC Bar data extraction is on but no
ANC Bar data is present
OP-47 data extraction is on but no
OP-47 data is present
The maximum bit-rate of the generic
ANC data output is exceeded. A
lower input ANC data rate is
required.
Unable to find VPS data on any
of the configured lines. Please
check the video input. For more
details on the type of VBI, see
the VBI status page
An invalid configuration has been
applied to Main Channel. Check
Video Standard and Profile
selection.
Advanced Encode Parameters are in
use.
PCR Exchange message not
received within timeout period
Set Rate message not received
within timeout period
Set Rate message received that is
too late to be applied, or is more
than 5 seconds early. The alarm is
cleared by the reception of a valid
Set Rate message, or Reflex being
disabled
Port Number
Alarm ID
1
010C400B
1
010C400C
1
010C400D
1
010C400E
1
010C400F
1
010C4010
1
010C4011
1
010C4012
0
010C4018
0
010C401C
1
010C4020
1
010C4021
1
010C4022
Source
Severity
VBI
minor
VBI
minor
VBI
minor
VBI
minor
VBI
minor
VBI
minor
VBI
warning
VBI
minor
VCM
minor
Module
VCM
warning
Module
VCM
warning
Module
VCM
warning
Module
VCM
warning
Module
EN/LZT 790 0023/1 R16A