Ericsson AVP 1000 Reference Manual page 55

Table of Contents

Advertisement

Parameter
Values
IGMP v2 [default]
Physical Data Interface <n>
Default MAC Address
aa:bb:cc:dd:ee:ff
Link Status
Link Up (1000)
Link Up (100)
Link Down
Link Up Time
days : hours : mins : secs
TX Packets
RX Packets
IP Address
aaa.bbb.ccc.ddd
Data Input (Ge1 and Ge2)
The unit has two Ethernet ports that can be used for data input, and responds to
ARPs and pings. Currently input data is not supported.
Data Output (Ge3 and Ge4)
The unit can generate one or more output Transport Streams from the components
produced by the option cards fitted. The IP output Transport Stream packets are
encapsulated in IP packets prior to being transmitted via the Ethernet Data ports.
The base unit does not provide any other interface through which Transport Streams
can be output.
Table 3.4
Ethernet Redundancy Modes
Redundancy Mode
Description
Active - Active
Both interfaces (Data 3 and Data 4)
simultaneously output the same output
TS.
EN/LZT 790 0023/1 R16A
Description
Uses version 2 of the IGMP protocol
The MAC address of the Gex
interface.
Link is up and the link speed is 1000
Mbps.
Link is up and the link speed is 100
Mbps.
Link is down.
The length of time that the link has
been up. If the link goes down this
value is reset to 0.
Number of IP packets transmitted
Number of IP packets received
Physical IP address of the data
interface
Type of Network
Same Network
Both interfaces are configured to be on the same network.
They have identical IP configuration, which is set using the
Interface Group IP address (Virtual IP Address). The Physical
Interface IP address does not need to be set and can remain at
0.0.0.0.
The unit automatically assigns the Source Address for output TS
to be the IP address of the Interface Group.
Getting Started
Comments
Read only parameter
Read only parameter
Read only parameter
Read only parameter
Read only parameter
Can remain set to 0.0.0.0
Must be unique if set
Setting the physical IP address allows
the interface to be pinged to validate
the connection.
Must be on the same subnet and
gateway as the virtual interface.
3-13

Advertisement

Table of Contents
loading

This manual is also suitable for:

Avp 2000Avp 1000 1ruAvp 3000Avp 1000 seriesAvp 1000 1ru seriesAvp 2000 series ... Show all

Table of Contents