Ericsson AVP 1000 Reference Manual page 213

Table of Contents

Advertisement

Parameter
Values
L-Band Frequency
950.000 MHz to 2150.000 MHz
Uplink Frequency
Nominal L-Band
-40.0 dBm to 5.0 dBm
Power
Reduced L-Band
-40.0 dBm to 5.0 dBm
Power
L-Band Spectrum
Normal, Inverted
Sense
L-Band Tilt
-0.040 dB/MHz to 0.040 dB/MHz
L-Band Up-converter
2500.000 MHz - 100000.000 MHz
Frequency
Up-converter Power
Off, 15V, 24V
Up-converter
Off, On
Reference
IF Output
Frequency Input Mode
IF Frequency, Uplink Frequency
IF Frequency
50.000 MHz to 180.000 MHz
Uplink Frequency
Nominal IF Power
-30.0 dBm to 5.0 dBm
Reduced IF Line-up
-30.0 dBm to 5.0 dBm
Power
IF Spectrum Sense
Normal, Inverted
IF Tilt
-0.040 dB/MHz to 0.040 dB/MHz
IF Up-converter
500.000 MHz to 100000.000 MHz
Frequency
EN/LZT 790 0023/1 R16A
Description
The center frequency of the signal output through the L-Band
output.
The frequency the signal is converted to by the up-converter
fed from the AVP 3000 Voyager through the L-Band output.
Uplink Frequency = Up-converter Frequency ± IF Frequency.
± depends on the Spectrum Sense.
The Nominal signal power output through the L-Band output
applied when the output is set to On (Nominal Power)
The Reduced signal output power applied when the output is set
to On (Reduced Power) when the output frequency is changed
or after a reboot if the Output State is allowed to stay on.
Specifies whether the spectrum is inverted or not inverted. It
has an effect on the Up-converter Frequency calculation.
The tilt applied in the L-band.
The oscillator frequency of the up-converter fed by the AVP
3000 Voyager through the L-Band output.
The voltage level to feed a downstream up-converter device.
Specifies whether to produce a 10-MHz reference for the
downstream up-converter device.
The mode how the frequency is treated. For IF Frequency the
RF center frequency of the respective output is directly
entered. For Uplink Frequency, the RF center frequency is
calculated from the Uplink Frequency and the Up-converter
Frequency.
The center frequency of the signal output through the IF
output.
The frequency the signal is converted to by the up-converter
fed from the AVP 3000 Voyager through the IF output.
Uplink Frequency = Up-converter Frequency ± IF Frequency.
± depends on the Spectrum Sense.
The Nominal signal power output through the IF output applied
when the output is set to On (Nominal Power).
The Reduced IF output power level applied when the output is
set to On (Reduced Power), when the output frequency is
changed or after a reboot if the Output State is allowed to stay
on.
Specifies whether the spectrum is inverted or not inverted. It
has an effect on the Up-converter Frequency calculation.
The tilt applied to the IF output signal.
The oscillator frequency of the up-converter fed by the AVP
3000 Voyager through the IF output.
Web GUI Control
5-37

Advertisement

Table of Contents
loading

This manual is also suitable for:

Avp 2000Avp 1000 1ruAvp 3000Avp 1000 seriesAvp 1000 1ru seriesAvp 2000 series ... Show all

Table of Contents