Ericsson AVP 1000 Reference Manual page 482

Table of Contents

Advertisement

Alarm Lists
Alarm
Internal Packetizer Error
Video Processor Failure
Video Processor Boot Failure
Video Processor Alive Count
Failure
Video 1 Input Lock
Video 1 Logo display error
VBI teletext not detected on
input
VBI video index not detected on
input
VBI CC608 closed captions not
detected on input
VBI ANC334 closed captions not
detected on input
VBI WSS not detected on input
VITC not detected on input
Selected Time code source not
detected
ANC Bar not detected on input
E-26
Description
A packetizer error has occurred on
at least one stream.
An unrecoverable failure has
occured on the Video Processor.
The services are affected and
intervention is required. See log for
more details
At least one video processor has not
booted
At least one video processor has not
incremented its alive count
No valid video found on video input.
Please check source connection.
There has been a problem when
attempting to display the logo.
Please check the logo file that has
been uploaded and X,Y position.
Unable to find teletext data on all of
the configured lines. Please check
the video input. For more details on
the type of VBI, see the VBI status
page.
Unable to find video index data on
any of the configured lines. Please
check the video input. For more
details on the type of VBI, see the
VBI status page.
Unable to find closed caption data
on any of the configured lines.
Please check the video input. For
more details on the type of VBI, see
the VBI status page.
Unable to find closed caption data
on any of the configured lines.
Please check the video input. For
more details on the type of VBI, see
the VBI status page.
Unable to find WSS (ETSI or AFD)
data on any of the configured lines.
Please check the video input. For
more details on the type of VBI, see
the VBI status page.
Unable to find VITC data on any of
the configured lines. Please check
the video input. For more details on
the type of VBI, see the VBI status
page.
For the selected Time code source
no Time code was found. If in auto
mode no source was found on any
input. Make sure that the correct
source is configured.
ANC Bar data extraction is on but no
ANC Bar data is present
Port Number
Alarm ID
1
010C0009
1
010C000A
1
010C7FE0
1
010C7FE1
1
010C4000
1
010C4001
1
010C4008
1
010C4009
1
010C400A
1
010C400B
1
010C400C
1
010C400D
1
010C400E
1
010C400F
Source
Severity
CE-x
warning
Analogue
Module
CE-x
critical
Analogue
Module
Video
critical
Module
Video
critical
Module
CE-x
critical
Analogue
CE-x
minor
Analogue
VBI
minor
VBI
minor
VBI
minor
VBI
minor
VBI
minor
VBI
minor
VBI
minor
VBI
minor
EN/LZT 790 0023/1 R16A

Advertisement

Table of Contents
loading

This manual is also suitable for:

Avp 2000Avp 1000 1ruAvp 3000Avp 1000 seriesAvp 1000 1ru seriesAvp 2000 series ... Show all