3.4.4 RS485 SIO

Two modes are available: the Modbus gateway mode in which the unit operates as a Modbus/RTU slave station, and the SIO
through mode in which the unit operates by means of serial communication per the Modbus/RTU and ASCII protocols.
Item
Power supply
Current consumption
Communication format
Communication method
Communication mode
Baud rate [bps] *2
Frame delay time
Slave address
Register address
Available function codes
Maximum send/receive buffer size
Bit length
Start bit
Stop bit
Parity
Cable length
Transmission path configuration
Communication method
Synchronization method
Transmission path format
Baud rate
Error control method
Communication cable
Number of units that can be connected
Surrounding air temperature
Surrounding humidity
Surrounding environment
Storage temperature
Storage humidity
Vibration resistance
Impact resistance
Protection degree
Weight
External dimensions [mm]
*1: The baud rate is set by the gateway parameter selection tool.
*2: If the host is a PLC, the PLC must have a RS485 or RS232C interface. If a RS232C interface is used, a SIO converter
(RCB-TU-SIO-*) is required.
18
Modbus gateway mode
1:1 communication connection
conforming to RS485
Asynchronous half-duplex
Modbus/RTU
9600
19200 38400
57600 115200 230400
t3.5
Fixed to 1.75 ms
Fixed to 63 (3FH)
Master ⇒
F600H to F647H
ROBONET
ROBONET ⇒
F700H to F747H
Master
Read Holding Register (03H)
Preset Single Register (06H)
Preset Multiple Register (10H)
100 m max. (master ⇐⇒ RGW-SIO)
IAI's dedicated multi-drop differential communication
Half-duplex
Start-stop method
Conforming to EIA RS485, 2-wire type
230.4 k [bps]
No parity bit, CRC *2
ROBONET communication connection circuit board (supplied), ROBONET
extension cable (when an extension unit is used)
16 axes max.
0 to 40°C
95% RH max. (non-condensing)
Free from corrosive gases, flammable gases, oil mist or powder dust.
-25 to 70°C
95% RH max. (non-condensing)
XYZ directions:
10 to 57 Hz, half amplitude – 0.035 mm (continuous) / 0.075 mm
(intermittent)
57 to 150 Hz – 4.9 m/s
XYZ directions:
2
147 mm/s
, 11 ms, half-sine wave pulse
34 W x 105 H x 73.3 D [mm]
Part 1 Specification
Specification
SIO through mode
24 VDC ± 10%
600 mA max.
1:N (1≤ N ≤ 16) communication
connection conforming to RS485
Modbus/RTU, ASCII
38400
t3.5
Axis number + 1 (01H to 10H)
01H to 07H
0FH, 10H, 11H, 17H
160 byte
8 bits
1 bit
1 bit
None
2
2
(continuous) / 9.8 m/s
IP20
Approx. 140 g
57600
115200
230400
Fixed to 1.75 ms
Arbitrary
(intermittent)