IAI RoboNet Operation Manual page 371

Table of Contents

Advertisement

Alarm List
STATUS
Simple
code
3
2
1
0
2
3
4
6
7
8
9
B
C
D
E
F
: Unlit
: Lit
*
Alarms denoted by
power is turned off once. Other alarms can be reset by inputting the reset signal.
Alarm
code
90
Software reset command with servo ON
91
Position number error during teaching
92
PWRT signal detection during movement
93
PWRT signal detection before home return
80
Movement command with servo OFF
Absolute position movement command before home
83
return
84
Movement command during home return
85
Position number error during movement
A7
Command deceleration error
F4
Unmatched PCB error
A1
Parameter data error
A2
Position data error
A3
Position-command information data error
B6
Phase-Z detection timeout
B7
Indeterminable magnetic pole
B8
Excitation detection error
BA
Home sensor not detected
BE
Home return timeout
C0
Excessive actual speed
C8
Overcurrent
C9
Overvoltage
CA
Overheat
CB
Current-sensor offset adjustment error
CC
Control power-supply voltage error
CE
Control power-supply voltage low
D8
Deviation overflow
D9
Software stroke limit over error
DC
Push & hold operation out-of-range error
C1
Servo error
D2
Excessive motor power-supply voltage
E0
Overload
F0
Driver logic error
E5
Encoder receive error
E8
Phase A/B open
E9
Phase A open
EA
Phase B open
ED
Absolute encoder error (1)
EE
Absolute encoder error (2)
EF
Absolute encoder error (3)
FA
CPU error
F5
Nonvolatile memory write verification error
F6
Nonvolatile memory write timeout
F8
Damaged nonvolatile memory data
in the "Reset method" field are cold-start alarms. These alarms cannot be reset unless the
Part 3 Maintenance
Alarm name
: Available X: Not available
*
Reset
RPCON RACON
method
x
x
x
x
x
x
x
x
x
x
x