1.2.3 Examples of Indicator Statuses Corresponding to Representative Alarms
Examples of indicator statuses corresponding to representative alarms are shown for CC-Link and DeviceNet systems.
(1)
CC-Link
: Lit
: Unlit
: Blinking
Gateway unit
ERROR-T
ERROR-C
(Orange)
(Orange)
(2)
DeviceNet
: Lit
: Unlit
: Blinking
Gateway unit
ERROR-T
ERROR-C
(Orange)
(Orange)
348
STATUS-1
STATUS-0
(Orange)
(Orange)
STATUS-1
STATUS-0
Green
Green
Green
Green
Green
Orange
Green
Green
Green
Green
Green
Green
Green
Green
Green
Green
Orange
Master
ERR
(Red)
Normal
The 24-V power supply of the gateway unit is turned off.
The power supply of the master is turned off.
The network cable is disconnected.
The ROBONET communication connection board is
detached.
The station number setting of the gateway unit is different
from the station number registered to the master.
The baud speed setting of the master is different from the
corresponding setting of the gateway unit.
The axis configuration (occupancy information) of the
gateway unit is different from the actual configuration.
The master network parameter for number of connected
units is different from the actual number of units.
The master network parameter for station type is wrong.
The master network parameter for number of occupied
station is wrong.
Master
NS
Green
Normal
Red
The 24-V power supply of the gateway unit is turned off.
The power supply of the master is turned off.
Red
The network cable is disconnected.
The ROBONET communication connection board is
Green
detached.
The station number setting of the gateway unit is different
Red
from the station number registered to the master.
The axis configuration (occupancy information) of the
Red
gateway unit is different from the actual configuration.
Red
The I/O size setting in the master scan list is wrong.
The station number setting (switch) of the master unit has
Red
been changed after the network was set up.
Part 3 Maintenance
Operation/condition
Operation/condition