3. Update the server firmware (UEFI and IMM) and adapter firmware. Important: Some cluster
solutions require specific code levels or coordinated code updates. If the device is part of a
cluster solution, verify that the latest level of code is supported for the cluster solution before
you update the code.
4. Replace the affected adapters.
5. Replace the riser card.
6. (Trained service technicians only) Replace the system board.
PCI 2 : PCI 3 : PCI 4 : PCI 5 : PCI 6 : PCI 7 :
• 806f0023-2101xxxx : Watchdog Timer expired for [WatchdogElementName]. (IPMI Watchdog)
This message is for the use case when an implementation has detected a Watchdog Timer Expired.
May also be shown as 806f00232101xxxx or 0x806f00232101xxxx
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0368
User Response
No action; information only.
• 806f0028-2101xxxx : Sensor [SensorElementName] is unavailable or degraded on management
system [ComputerSystemElementName]. (TPM Cmd Failures)
This message is for the use case when an implementation has detected a Sensor is Unavailable or
degraded.
May also be shown as 806f00282101xxxx or 0x806f00282101xxxx
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
Appendix A. Integrated Management Module II (IMM2) error messages