Lenovo System x3500 M5 Type 5464 Installation And Service Manual page 543

Hide thumbs Also See for System x3500 M5 Type 5464:
Table of Contents

Advertisement

Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0100
User Response
1. Reconnect the power cords.
2. Check power supply n LED.
3. See Power-supply LEDs for more information. (n = power supply number)
806f030c-2001xxxx : Scrub Failure for [PhysicalMemoryElementName] on Subsystem
[MemoryElementName]. (DIMM 1)
This message is for the use case when an implementation has detected a Memory Scrub failure.
May also be shown as 806f030c2001xxxx or 0x806f030c2001xxxx
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0136
User Response
Note: Each time you install or remove a DIMM, you must disconnect the server from the power
source; then, wait 10 seconds before restarting the server.
1. Refer to TIP H212293 for minimum code level.
2. Check the Lenovo support website for an applicable retain tip or firmware update that applies
to this memory error.
3. Manually re-enable all affected DIMMs.
Appendix A. Integrated Management Module II (IMM2) error messages
527