Lenovo System x3500 M5 Type 5464 Installation And Service Manual page 642

Hide thumbs Also See for System x3500 M5 Type 5464:
Table of Contents

Advertisement

6. (Trained technician only) Replace the system board.
• 806f0607-0302xxxx : An SM BIOS Uncorrectable CPU complex error for [ProcessorElementName]
has asserted. (CPU 2)
This message is for the use case when an SM BIOS Uncorrectable CPU complex error has asserted.
May also be shown as 806f06070302xxxx or 0x806f06070302xxxx
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - CPU
SNMP Trap ID
40
CIM Information
Prefix: PLAT ID: 0816
User Response
1. Update the latest level of system firmware and device drivers are installed for all adapters and
standard devices, such as UEFI, IMM Ethernet,and SAS. Important: Some cluster solutions
require specific code levels or coordinated code updates. If the device is part of a cluster
solution, verify that the latest level of code is supported for the cluster solution before you
update the code.
2. Run the DSA program.
3. Reseat the adapter.
4. Replace the adapter.
5. (Trained technician only) Replace microprocessor n. (n = microprocessor number)
6. (Trained technician only) Replace the system board.
• 806f0607-2584xxxx : An SM BIOS Uncorrectable CPU complex error for [ProcessorElementName]
has asserted. (All CPUs)
This message is for the use case when an SM BIOS Uncorrectable CPU complex error has asserted.
May also be shown as 806f06072584xxxx or 0x806f06072584xxxx
Severity
Error
Serviceable
626
System x3500 M5 Installation and Service Guide

Advertisement

Table of Contents
loading

Table of Contents