Lenovo System x3500 M5 Type 5464 Installation And Service Manual page 437

Hide thumbs Also See for System x3500 M5 Type 5464:
Table of Contents

Advertisement

2. Re-enable mirroring in the Setup utility.
• 806f0005-1701xxxx : The Chassis [PhysicalPackageElementName] was opened. (Chassis Error)
This message is for the use case when the Chassis has been opened.
May also be shown as 806f00051701xxxx or 0x806f00051701xxxx
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
Warning - Other
SNMP Trap ID
60
CIM Information
Prefix: PLAT ID: 0004
User Response
1. Open side cover to check airbuffle be instsalled well.
2. Close side cover and lock the latch.
3. Power On the system.
• 806f0007-0301xxxx : [ProcessorElementName] has Failed with IERR. (CPU 1)
This message is for the use case when an implementation has detected a Processor Failed - IERR
Condition.
May also be shown as 806f00070301xxxx or 0x806f00070301xxxx
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - CPU
SNMP Trap ID
40
Appendix A. Integrated Management Module II (IMM2) error messages
421