Lenovo System x3500 M5 Type 5464 Installation And Service Manual page 712

Hide thumbs Also See for System x3500 M5 Type 5464:
Table of Contents

Advertisement

1. Reseat the DIMM, and then restart the server.
2. Replace DIMM n. (n = DIMM number)
806f090c-200exxxx : [PhysicalMemoryElementName] on Subsystem [MemoryElementName]
Throttled. (DIMM 14)
This message is for the use case when an implementation has detected Memory has been Throttled.
May also be shown as 806f090c200exxxx or 0x806f090c200exxxx
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
22
CIM Information
Prefix: PLAT ID: 0142
User Response
1. Reseat the DIMM, and then restart the server.
2. Replace DIMM n. (n = DIMM number)
806f090c-200fxxxx : [PhysicalMemoryElementName] on Subsystem [MemoryElementName]
Throttled. (DIMM 15)
This message is for the use case when an implementation has detected Memory has been Throttled.
May also be shown as 806f090c200fxxxx or 0x806f090c200fxxxx
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
22
696
System x3500 M5 Installation and Service Guide

Advertisement

Table of Contents
loading

Table of Contents