Lenovo System x3500 M5 Type 5464 Installation And Service Manual page 790

Hide thumbs Also See for System x3500 M5 Type 5464:
Table of Contents

Advertisement

1. Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling
the drive.
2. Make sure that the disk firmware and RAID controller and backplane firmware are at the latest
level.
3. Check the SAS cable.
4. Replace the hard disk drive.
816f000d-0419xxxx : The Drive [StorageVolumeElementName] has been removed from unit
[PhysicalPackageElementName]. (Drive 25)
This message is for the use case when an implementation has detected a Drive has been Removed.
May also be shown as 816f000d0419xxxx or 0x816f000d0419xxxx
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0163
User Response
1. Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling
the drive.
2. Make sure that the disk firmware and RAID controller and backplane firmware are at the latest
level.
3. Check the SAS cable.
4. Replace the hard disk drive.
816f000d-041axxxx : The Drive [StorageVolumeElementName] has been removed from unit
[PhysicalPackageElementName]. (Drive 26)
This message is for the use case when an implementation has detected a Drive has been Removed.
May also be shown as 816f000d041axxxx or 0x816f000d041axxxx
Severity
774
System x3500 M5 Installation and Service Guide

Advertisement

Table of Contents
loading

Table of Contents