– RAID 5/50 (1 GB Cache) with optional FoD RAID 6/60 and SED upgrade
– RAID 5/50 (1 GB Flash) with optional FoD RAID 6/60 and SED upgrade
– RAID 5/50 (2 GB Flash) with optional FoD RAID 6/60 and SED upgrade
– RAID 5/50 (4 GB Flash) with optional FoD RAID 6/60 and SED upgrade
– FoD RAID 6/60 Upgrade
– FoD Zero Cache/RAID 5/50
– FoD Performance Accelerator
– FoD SSD Caching Enabler
Integrated functions:
• Integrated Management Module II (IMM2), which consolidates multiple management functions in a
single chip.
• Broadcom 5719 Quad Port Gigabit Ethernet controller with Wake on LAN support
• Serial over LAN (SOL) and serial redirection over Telnet or Secure Shell (SSH)
• One systems-management 1 Gb Ethernet port for connection to a dedicated systems-management
network. This system management connector is dedicated to the IMM2.1 functions.
• Light path diagnostics
• Six Universal Serial Bus ports on the front of server
– Two (USB 2.0) on front of server
– Two (USB 2.0) on rear of server
– Two (USB 3.0) on rear of server
• One internal USB port for optional USB flash device with embedded hypervisor
• One internal USB tape connector
Video controller (integrated into IMM2.1):
• Matrox G200eR2
Note: The maximum video resolution is 1600 x 1200 at 75 Hz.
– SVGA compatible video controller
– DDR3 528 MHz SDRAM video memory controller
– Avocent Digital Video Compression
– 16 MB of video memory (not expandable)
Size:
• Tower
– 5 U
– Height: 440 mm (17.3 in.)
– Depth: 720 mm (28.3 in.)
– Width: 217.5 mm (8.6 in.)
– Weight: approximately 45.5 kg (100.3 lb) when fully configured or 30.8 kg (67.9 lb) minimum
• Rack
– 5 U
– Height: 217.5 mm (8.6 in.)
– Depth: 705.5 mm (27.8 in.)
.
Chapter 1
The Lenovo System x3500 M5 Type 5464 server