1. Reseat the DIMM, and then restart the server.
2. Replace DIMM n. (n = DIMM number)
• 806f0a07-0301xxxx : [ProcessorElementName] is operating in a Degraded State. (CPU 1)
This message is for the use case when an implementation has detected a Processor is running in the
Degraded state.
May also be shown as 806f0a070301xxxx or 0x806f0a070301xxxx
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
Warning - CPU
SNMP Trap ID
42
CIM Information
Prefix: PLAT ID: 0038
User Response
1. Make sure that the fans are operating, that there are no obstructions to the airflow (front and
rear of the server), that the air baffles are in place and correctly installed, and that the server
cover is installed and completely closed.
2. Check the ambient temperature. You must be operating within the specifications.
3. Make sure that the heat sink for microprocessor n is installed correctly.
4. (Trained technician only) Replace microprocessor n. (n = microprocessor number)
• 806f0a07-0302xxxx : [ProcessorElementName] is operating in a Degraded State. (CPU 2)
This message is for the use case when an implementation has detected a Processor is running in the
Degraded state.
May also be shown as 806f0a070302xxxx or 0x806f0a070302xxxx
Severity
Warning
Serviceable
Yes
Automatically notify support
No
702
System x3500 M5 Installation and Service Guide