Lenovo System x3500 M5 Type 5464 Installation And Service Manual page 30

Hide thumbs Also See for System x3500 M5 Type 5464:
Table of Contents

Advertisement

• 24-hour support center
• Automatic error retry and recovery
• Automatic restart on nonmaskable interrupt (NMI)
• Automatic restart after a power failure
• Backup basic input/output system switching under the control of the Integrated Management Module II
(IMM2)
• Built-in monitoring for fan, power, temperature, voltage, and power-supply redundancy
• Cable-presence detection on most connectors
• Chipkill memory protection
• Single-device data correction (SDDC) for x4 DRAM technology DIMMs (available on 16 GB DIMMs only).
Ensures that data is available on a single x4 DRAM DIMM after a hard failure of up to two DRAM DIMMs.
One x4 DRAM DIMM in each rank is reserved as a space device.
• Diagnostic support for ServeRAID and Ethernet adapters
• Error codes and messages
• Error correcting code (ECC) L3 cache and system memory
• Full Array Memory Mirroring (FAMM) redundancy
• Hot-swap cooling fans with speed-sensing capability
• Hot-swap hard disk drives
• Hot-swap power supplies
• Information and light path diagnostics LED panels
• Integrated Management Module II (IMM2)
• Light path diagnostics LEDs for DIMMs, microprocessors, hard disk drives, solid state drives, power
supplies, and fans
• Memory mirroring and memory sparing support
• Memory error correcting code and parity test
• Memory downsizing (non-mirrored memory). After a restart of the server after the memory controller
detects a non-mirrored uncorrectable error and the memory controller cannot recover operationally, the
IMM2.1 logs the uncorrectable error and informs POST. POST logically maps out the memory with the
uncorrectable error, and the server restarts with the remaining installed memory.
• Menu-driven setup, system configuration, and redundant array of independent disks (RAID) configuration
programs
• Microprocessor built-in self-test (BIST), internal error signal monitoring, internal thermal trip signal
monitoring, configuration checking, and microprocessor and voltage regulator module failure identification
through light path diagnostics
• Nonmaskable interrupt (NMI) button
• Parity checking on the PCIe buses
• Power management: compliance with Advanced Configuration and Power Interface (ACPI)
• Power-on self-test (POST)
• Proactive Platform Alerts (including Predictive Failure Analysis and Self-Monitoring, Analysis and
Reporting Technology alerts): microprocessors, voltage regulators, memory, internal storage (SAS/SATA
hard disk drives and solid-state drives, NVMe solid-state drives, M.2 storage, flash storage adapters),
fans, power supplies, RAID controllers, and server ambient and sub-component temperatures
• Redundant Ethernet capabilities with failover support
• Redundant hot-swap power supplies and redundant hot-swap fans
• Redundant network interface card (NIC) support
• Remote system problem-determination support
• ROM-based diagnostics
• ROM checksums
• Serial Presence Detection (SPD) on memory, VPD on system board, power supply, and hard disk drive or
solid state drive backplanes, microprocessor and memory expansion tray, and Ethernet adapters
• Single-DIMM isolation of excessive correctable error or multi-bit error by the Unified Extensible Firmware
Interface (UEFI)
• Solid-state drives
• Standby voltage for systems-management features and monitoring
14
System x3500 M5 Installation and Service Guide

Advertisement

Table of Contents
loading

Table of Contents