Lenovo System x3500 M5 Type 5464 Installation And Service Manual page 433

Hide thumbs Also See for System x3500 M5 Type 5464:
Table of Contents

Advertisement

Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Fan Failure
SNMP Trap ID
11
CIM Information
Prefix: PLAT ID: 0802
User Response
1. Make sure that the connectors on fan n are not damaged.
2. Make sure that the fan n connectors on the system board are not damaged.
3. Make sure that the fans are correctly installed.
4. Reseat the fans.
5. Replace the fans. (n = fan number)
• 800b010c-2581xxxx : Redundancy Lost for [RedundancySetElementName] has asserted. (Backup
Memory)
This message is for the use case when Redundancy Lost has asserted.
May also be shown as 800b010c2581xxxx or 0x800b010c2581xxxx
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0802
User Response
1. Check the system-event log for DIMM failure events (uncorrectable or PFA) and correct the
failures.
2. Re-enable mirroring in the Setup utility.
Appendix A. Integrated Management Module II (IMM2) error messages
417

Advertisement

Table of Contents
loading

Table of Contents