CIM Information
Prefix: PLAT ID: 0042
User Response
1. Update the latest level of system firmware and device drivers are installed for all adapters and
standard devices, such as UEFI, IMM Ethernet,and SAS. Important: Some cluster solutions
require specific code levels or coordinated code updates. If the device is part of a cluster
solution, verify that the latest level of code is supported for the cluster solution before you
update the code.
2. Run the DSA program.
3. Reseat the adapter.
4. Replace the adapter.
5. (Trained technician only) Replace microprocessor n. (n = microprocessor number)
6. (Trained technician only) Replace the system board.
• 806f0007-0302xxxx : [ProcessorElementName] has Failed with IERR. (CPU 2)
This message is for the use case when an implementation has detected a Processor Failed - IERR
Condition.
May also be shown as 806f00070302xxxx or 0x806f00070302xxxx
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - CPU
SNMP Trap ID
40
CIM Information
Prefix: PLAT ID: 0042
User Response
1. Update the latest level of system firmware and device drivers are installed for all adapters and
standard devices, such as UEFI, IMM Ethernet,and SAS. Important: Some cluster solutions
require specific code levels or coordinated code updates. If the device is part of a cluster
solution, verify that the latest level of code is supported for the cluster solution before you
update the code.
2. Run the DSA program.
3. Reseat the adapter.
4. Replace the adapter.
5. (Trained technician only) Replace microprocessor n. (n = microprocessor number)