Lenovo System x3500 M5 Type 5464 Installation And Service Manual page 417

Hide thumbs Also See for System x3500 M5 Type 5464:
Table of Contents

Advertisement

1. Make sure that the fans are operating, that there are no obstructions to the airflow (front and
rear of the server), that the air baffles are in place and correctly installed, and that the server
cover is installed and completely closed.
2. Check the ambient temperature. You must be operating within the specifications (see Features
and specifications for more information).
3. Make sure that the heat sink for microprocessor n is installed correctly.
4. (Trained technician only) Replace microprocessor n. (n = microprocessor number)
• 80070202-0701xxxx : Sensor [SensorElementName] has transitioned to critical from a less severe
state. (SysBrd Vol Fault)
This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
May also be shown as 800702020701xxxx or 0x800702020701xxxx
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Voltage
SNMP Trap ID
1
CIM Information
Prefix: PLAT ID: 0522
User Response
1. Check the system-event log.
2. Check for an error LED on the system board.
3. Replace any failing device.
4. Check for a server firmware update. Important: Some cluster solutions require specific code
levels or coordinated code updates. If the device is part of a cluster solution, verify that the latest
level of code is supported for the cluster solution before you update the code.
5. (Trained technician only) Replace the system board.
• 80070204-0a01xxxx : Sensor [SensorElementName] has transitioned to critical from a less severe
state. (PS 1 Fan Fault)
This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
May also be shown as 800702040a01xxxx or 0x800702040a01xxxx
Appendix A. Integrated Management Module II (IMM2) error messages
401

Advertisement

Table of Contents
loading

Table of Contents