Lenovo System x3500 M5 Type 5464 Installation And Service Manual page 794

Hide thumbs Also See for System x3500 M5 Type 5464:
Table of Contents

Advertisement

816f000d-041fxxxx : The Drive [StorageVolumeElementName] has been removed from unit
[PhysicalPackageElementName]. (Drive 31)
This message is for the use case when an implementation has detected a Drive has been Removed.
May also be shown as 816f000d041fxxxx or 0x816f000d041fxxxx
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0163
User Response
1. Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling
the drive.
2. Make sure that the disk firmware and RAID controller and backplane firmware are at the latest
level.
3. Check the SAS cable.
4. Replace the hard disk drive.
816f000f-2201ffff : The System [ComputerSystemElementName] has detected a POST Error
deassertion. (ABR Status)
This message is for the use case when an implementation has detected that Post Error has deasserted.
May also be shown as 816f000f2201ffff or 0x816f000f2201ffff
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
778
System x3500 M5 Installation and Service Guide

Advertisement

Table of Contents
loading

Table of Contents