Lenovo System x3500 M5 Type 5464 Installation And Service Manual page 663

Hide thumbs Also See for System x3500 M5 Type 5464:
Table of Contents

Advertisement

Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0176
User Response
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Replace the RAID adapter.
5. Replace the hard disk drive that is indicated by a lit status LED.
806f070c-2001xxxx : Configuration Error for [PhysicalMemoryElementName] on Subsystem
[MemoryElementName]. (DIMM 1)
This message is for the use case when an implementation has detected a Memory DIMM configuration
error has been corrected.
May also be shown as 806f070c2001xxxx or 0x806f070c2001xxxx
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0126
User Response
Make sure that DIMMs are installed and following the memory population chart in the system
publication.
806f070c-2002xxxx : Configuration Error for [PhysicalMemoryElementName] on Subsystem
[MemoryElementName]. (DIMM 2)
This message is for the use case when an implementation has detected a Memory DIMM configuration
error has been corrected.
May also be shown as 806f070c2002xxxx or 0x806f070c2002xxxx
Appendix A. Integrated Management Module II (IMM2) error messages