Lenovo System x3500 M5 Type 5464 Installation And Service Manual page 340

Hide thumbs Also See for System x3500 M5 Type 5464:
Table of Contents

Advertisement

User Response
To avoid losing older log entries, save the log as a text file and clear the log.
• 40000027-00000000 : Platform Watchdog Timer expired for [arg1]. ()
This message is for the use case when an implementation has detected a Platform Watchdog Timer
Expired
May also be shown as 4000002700000000 or 0x4000002700000000
Severity
Error
Serviceable
No
Automatically notify support
No
Alert Category
System - OS Timeout
SNMP Trap ID
21
CIM Information
Prefix: IMM ID: 0039
User Response
Complete the following steps until the problem is solved:
1. Reconfigure the watchdog timer to a higher value.
2. Make sure that the IMM Ethernet-over-USB interface is enabled.
3. Reinstall the RNDIS or cdc_ether device driver for the operating system.
4. Disable the watchdog.
5. Check the integrity of the installed operating system.
• 40000028-00000000 : Management Controller Test Alert Generated by [arg1]. ()
This message is for the use case where a user has generated a Test Alert.
May also be shown as 4000002800000000 or 0x4000002800000000
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - other
324
System x3500 M5 Installation and Service Guide

Advertisement

Table of Contents
loading

Table of Contents