• 816f0113-0301xxxx : System [ComputerSystemElementName] has recovered from a bus timeout.
(CPU 1 PECI)
This message is for the use case when an implementation has detected that a system has recovered from
a Bus Timeout.
May also be shown as 816f01130301xxxx or 0x816f01130301xxxx
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0225
User Response
1. (Trained technician only) Replace microprocessor n (see Removing a microprocessor and heat
sink and Replacing a microprocessor and heat sink).
2. If the problem persists and there is no other CPU with the same error indication, replace the
system board.
3. (Trained technician only) Replace the system board (see Removing the system board and
Replacing the system board). (n = microprocessor number)
• 816f0113-0302xxxx : System [ComputerSystemElementName] has recovered from a bus timeout.
(CPU 2 PECI)
Appendix A. Integrated Management Module II (IMM2) error messages
819