Lenovo System x3500 M5 Type 5464 Installation And Service Manual page 645

Hide thumbs Also See for System x3500 M5 Type 5464:
Table of Contents

Advertisement

SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0176
User Response
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Replace the RAID adapter.
5. Replace the hard disk drive that is indicated by a lit status LED.
• 806f060d-0402xxxx : Array [ComputerSystemElementName] has failed. (Drive 2)
This message is for the use case when an implementation has detected that an Array Failed.
May also be shown as 806f060d0402xxxx or 0x806f060d0402xxxx
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0176
User Response
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Replace the RAID adapter.
5. Replace the hard disk drive that is indicated by a lit status LED.
• 806f060d-0403xxxx : Array [ComputerSystemElementName] has failed. (Drive 3)
This message is for the use case when an implementation has detected that an Array Failed.
May also be shown as 806f060d0403xxxx or 0x806f060d0403xxxx
Appendix A. Integrated Management Module II (IMM2) error messages
629

Advertisement

Table of Contents
loading

Table of Contents