GRAPHTEC gl7000 User Manual page 158

Module-expanding, high speed, multi-function, multi-channel data platform
Hide thumbs Also See for gl7000:
Table of Contents

Advertisement

CHAPTER 3 Measure and Set
<High voltage module>
Item select
Off
DC
AC
DC-RMS
AC-RMS
<DC strain module>
Item select
Off
Strain gauge
Strain gauge
sensor
Voltage
Resistance
<Charge module>
Item select
Off
Charge
IEPE
DC
AC
Charge-RMS
IEPE-RMS
DC-RMS
AC-RMS
(11)-1-2 Slope (Slope of the pulse)
Sets the pulse count slope (direction) when setting the pulse on a Logic/Pulse module.
Item select
L
H
(11)-1-3 Number of pulses per revolution
When the input pulse is specified as the number of revolutions, set the number of pulses per revolution.
As the number of pulses per revolution set here is 1 revolution, calculate the number of revolutions per
minute (RPM).
For example, if "100" is set, 1 rotation is judged when 100 pulses have been input.
<Formula>
Rotation (rpm) = Pulse input frequency ÷ Number of pulses per revolution × 60 (1min.)
<Ex.>
Number of pulses per revolution : 100 (1 rotation is judged when 100 pulses have been input.)
Pulse entry
Number of revolutions
3-92
Does not measure the input signal. Waveform, digital display also not carried out.
The input signal is measured with DC coupling.
The input signal is measured with AC coupling.
The input signal is measured with DC coupling. The measured value is an effective value.
The input signal is measured with AC coupling. The measured value is an effective value.
The input signal is not measured. The waveforms and digital values are not displayed.
This is used for Quarter bridge, Half bridge or Full bridge.
The sensor for Full bridge 4 wires and 6 wires is used to measure.
This is used to measure the DC voltage.
1Ω to 50kΩ resistance is measured.
The input signal is not measured. The waveforms and digital values are not displayed.
The acceleration sensor signal that conforms to the IEPE specification is measured.
The measured value is an effective value.
The acceleration sensor signal that conforms to the IEPE specification is measured.
The input signal is measured with DC coupling.
The input signal is measured with AC coupling.
The acceleration sensor signal that conforms to the charge specification is measured.
The measured value is an effective value.
The acceleration sensor signal that conforms to the charge specification is measured.
The input signal is measured with DC coupling. The measured value is an effective value.
The input signal is measured with AC coupling. The measured value is an effective value.
Counts the falling edges of the pulse.
Counts the rising edges of the pulse.
: 1000 Hz (1000 pulses per sec.)
: 600 RPM (600 RPM per min.)
Description
Description
Description
Description

Advertisement

Table of Contents
loading

Table of Contents