GRAPHTEC gl7000 User Manual page 140

Module-expanding, high speed, multi-function, multi-channel data platform
Hide thumbs Also See for gl7000:
Table of Contents

Advertisement

CHAPTER 3 Measure and Set
(9)-5 NTP server
Input the domain name of the time server (NTP server) in use.
(9)-6 Time zone
Sets the time zone for the area the GL7000 is being used in.
(9)-7 Synchronized interval
Sets the interval for synchronizing to the time server. Time synchronization is performed in the way set in
synchronization mode settings when the synchronization interval is up. The elapsed time measurement can
be set when this item is set or following startup.
(9)-8 Adjust mode
Sets the synchronization method to the clock server.
Item select
Step
Slew
(9)-9 Connection test
Carries out a connection test to the time server.
A message is displayed when carrying out the connection test. If connection cannot be made, please check
the settings and test again.
* If the connection test is OK, the message below is displayed.
If the factory settings are used and the setting conditions are initialized, the settings for the FTP server are also
initialized.
If the configuration of the modules is changed, the setting conditions is initialized and then the settings for FTP serve
are also initialized.
3-74
When the synchronization interval elapses, the time is immediately set using the server time.
Even if the synchronization interval elapses, immediate synchronization is not carried out.
The time is gradually synchronized to the server time.
The adjustment amount is approx. 43 seconds/day. (20 seconds is about 10ms of adjustment
amount.)