Connecting Accessory Devices - HySecurity StrongArmPark DC Programming And Operations Manual

With hysecurity smart dc controller mx3650-01 revision d
Hide thumbs Also See for StrongArmPark DC:
Table of Contents

Advertisement

C
onneCtIng
Devices, such as gate edge sensors and photoelectric beams, must be installed to protect against entrapment.
These secondary entrapment protection devices are required for the gate installation to be in compliance with
UL 325 Safety Standards. Most Crash gates are site-specific when it comes to safety standard compliance, and
power requirements fall under UL 508A. Always check your local area codes and comply with all regulations.
Standard accessory (entrapment and loop wire) connections are shown in the following illustration. All
accessories require a minimum of two connections:
a device input
a Common Bus Terminal (COM)
Two power
supplies (2
terminals each)
are available
for peripheral
connections:
24VDC & 12VDC
NOTE: Each
power supply
(and its
corresponding
terminals) can
be used in any
combination to
COMMON
draw the available
TERMINALS
1A maximum.
Access controls
(Ex. Card reader, keypad)
Parking Site Use
TRANSIENT
The label for the
USER
Smart DC Controller
accommodates
CLOSE
arming loops and
establishes which
open commands need
SPECIAL
to be wired for vehicle
USER
counts (transient,
TENANT
special, and tenant
"user types").
USER
The software identifies
the access control
SPARE
inputs and uses the
arming loops to
EYE
control relay and
CLOSE
network outputs.
EXIT
LOOP
BLOCK
EXIT
INNER
ARMING
OUTER
ARMING
38
MX3650-01 Rev. D
a
d
CCessorY
COM
COM
COM
COM
COM
COM
COM
COM
STOP
OPEN
CLOSE
OPEN
P ARTIAL
SENSOR 1
SENSOR 3
EXIT
LOOP
BLOCK
EXIT
IN OBS
LOOP
OUT OBS
LOOP
CENTER
LOOP
Press bu�on to light
SENSOR 2
ac�ve inputs.
SENSOR
COM
+ 24 V
EMERG
OPEN
SHOW
LEDs
Radio receiver
StrongArmPark DC Programming & Operations
evICes
Mul�-colored LED
indicates power and gate
status.
RS-232
Ethernet
expansion
Red LED
heart
beat
indicates
processor is
working.
USB PORT
USER RELAY 2
Solid state
NOTE: The most current software must be loaded on
your Smart DC Controller and the operator identified as
OT 14 for the Parking Site labeled inputs to be effective.
EXIT LOOP
INSIDE LOOP
(Inner Arming
Loop)
OUTSIDE LOOP
(Outer Arming
Loop)
CENTER LOOP
RS-485
COMMUNICATION
LOOP
Not to Scale
© 2017
www.hysecurity.com
Hy5B

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents