Spring & Physical Stop Lever Assembly; Set Handing - HySecurity StrongArmPark DC Programming And Operations Manual

With hysecurity smart dc controller mx3650-01 revision d
Hide thumbs Also See for StrongArmPark DC:
Table of Contents

Advertisement

s
& p
prIng
HYsICal
12
Remove spring tension. Use a crescent wrench (or 12
7
point ratchet) to remove the square base nut and washer.
NOTE: You do not need to loosen the nut on the top of
the bracket. It helps keep the spring tension at factory
settings.
All thread rod
Square top nut
Square base nut
12
Swap physical stop lever hardware. Use a ¾-inch deep well
8
socket and box end wrench to remove the fasteners securing
the eyebolt. Then, loosen and remove the fasteners from
the other the physical stop lever and swap positions on the
physical stop levers.
Physical stop
levers.
Swap
locations
(Remove/
Replace
fasteners
and
eyebolt.)
78
MX3650-01 Rev. D
s
l
top
ever
NOTE: For better access, you
can rotate the gear box to
reposition the physical stop
levers.
H
StrongArmPark DC 14
NOTE: If the arm length is less than 11 ft (3.3 m), disconnect
the spring from the physical stop lever.
Eyebolt
12
10
Spring
Square base nut
StrongArmPark DC Programming & Operations
a
ssemBlY
12
Reverse the steps found
9
on page 1.
• Insert the all thread and
re-attach the base nut.
• Tighten the two base nuts to
the required "H" dimension. See chart.
Arm Length
Spring Setting (H)
11 - 12 ft (3.6 m) 3.5 inches (89 mm)
12 - 13 ft (4 m)
3 inches (76 mm)
13 - 14 ft (4.3 m) 2.5 inches (63 mm)
• Replace the motor and reconnect the 3 wire
leads.
• Replace the drive belt and adjust the tension
by sliding the motor plate and tightening
its 4 bolts.
• Replace the physical stop bracket
removed in step 3.
• Replace the drive belt cover.

Set Handing

Turn ON the DC power switch and set the handing
using the Smart DC Controller.
• Press MENU twice.
• Press and hold OPEN and RESET, and then release.
• Press NEXT until GATE HANDING appears.
• Press SELECT. SH blinks.
• Press NEXT to set the handing (Left or Right).
• To accept what is being displayed, press SELECT.
• To exit Menu mode, press RESET.
• Turn OFF the DC power switch.
• Install the breakaway bracket by aligning its splines
with the gear box.
• Assemble the arm, apply power, and re-learn limits.
• Finish the site
installation.
Z\zn to Z\,-inch
(1.6 to 3.2 mm)
SH R (RIGHT)
GATE HANDING
OPEN
CLOSE
STOP
MENU
PREV
NEXT
SELECT
© 2017
www.hysecurity.com
RESET

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents