StrongArmPark DC uses a dynamic reversing sensor. A solid immovable object blocking the gate will trip the
sensor and cause the operator to stop, reverse and enter safe mode.
Available settings (0, 1, and 2), accessed through the Installer Menu,
allow you to adjust the level of sensitivity. A maximum sensitivity of
zero (0) is the default setting.
When changing the setting, consider the site design and vehicular
gate traffic. It is recommended that you use the most sensitive setting
while still allowing for reliable gate operation.
To adjust the sensitivity, take the following steps:
At a gate status display, press the MENU button twice. The CLOSE TIMER
display appears.
Simultaneously, press the OPEN and RESET buttons to enter the Installer
Menu.
Release the buttons and the LEARN LIMITS display appears.
Press NEXT until the display, shown in Figure 1, appears. The factory default
setting is 0.
Use the SELECT and NEXT buttons to navigate and change the number on
the display.
Press SELECT again to accept what appears on the display.
To exit the Installer Menu, press the MENU button. The gate status appears
in the display indicating you have returned to Run Mode.
NOTE: On the StrongArmParkDC 14, you can also adjust the spring tension,
in combination with the dynamic reversing sensor. A spring that is too tight
can cause a false alert.
Other adjustments involved in the arm reversing include:
SR (IES Sensor Logic) provides two settings: Half second reversal or
full open upon trigger. The default is ½ second reversal.
For more information, review settings in the Installer Menu table.
If the dynamic reversing sensor is tripped, a fault occurs and SAFE MODE
will appear on the display. For more information, refer to the System
Diagnostic Messages on page 59.
66
MX3650-01 Rev. D
d
r
YnamIC
eversIng
StrongArmPark DC Programming & Operations
s
ensor
SE 0
IES SENSITIVITY
Figure 1: StrongArmPark DC
Adjusting the dynamic reversing
sensitivity
HYSECURITY
GATE CLOSED
OPEN
CLOSE
PREV
NEXT
CT 0 (OFF)
CLOSE TIMER
OPEN
CLOSE
PREV
NEXT
UC 2
USAGE CLASS
CLOSE
OPEN
PREV
NEXT
SE 2
IES SENSITIVITY
OPEN
CLOSE
PREV
NEXT
STOP
MENU
RESET
SELECT
STOP
MENU
RESET
SELECT
MENU
STOP
RESET
SELECT
STOP
MENU
RESET
SELECT