Table 4: Installer Menu

Installer Menu
OT 0
0 = operator type
12 = SwingSmart DC 20 & DCS 20
Set Operator Type
14 = StrongArmPark DC 10 & DC14
15 = SlideSmart DC 15 &
16 = SlideSmart DC 10F &
MN 0
0 = model type unknown
Model Number
1 = Model 10
2 = Model 14
LL 0 (OFF)
0 = Normal setting
1 = Erases learned limit positions
Learn Limit Reset
UC 0
0 = gate disabled
1 = Family dwelling (1 to 4 units)
Usage Class
2 = Multi-family & commercial
3 = Light industrial*
4 = Industrial/guarded secure*
*Not serving the general public
SH 0
0 = gate disabled
R = viewed from the secure side, the
Gate Handing
arm lifts right to open
L = viewed from the secure side, the
arm lifts left to open
OS 1
DC10
1 = 2.5 seconds 1 = 3.5 seconds
Open Speed
2 = 2.0 seconds
3 = 1.5 seconds
CS 1
1 = 2.5 seconds 1 = 3.5 seconds
2 = 2.0 seconds
Close Speed
3 = 1.5 seconds
FD 0 (OFF)
0 = user settings
Load Factory Defaults
1 = reload factory settings
DG 0 (OFF)
0 = solo operator
Dual Gate
1 = Slave unit
2 = Master unit
3 = Sally Port A
4 = Sally Port B
www.hysecurity.com
© 2017
Table 4: Installer Menu
Setting Options
Solar
DCS 10 Solar & DCS 14 Solar
DCS 15 Solar
DCS 10F Solar
DC14
2 = 3.0 seconds
3 = 2.5 seconds
2 = 3.0 seconds
3 = 2.5 seconds
Menu Tasks & Explanations
Select the appropriate number for the
operator.
NOTE: This menu item only appears if the
Smart DC Controller is being replaced.
CAUTION: If you are replacing an SDC
board, remember to transfer the operator's
menu settings from the existing board
to the replacement board. Refer to the
installation instructions that accompany the
replacement SDC board.
Select the type of StrongArmPark DC model
used at the site. NOTE: This menu item only
appears when you set the OT (operator type).
Set to option 1, the system resets to
accommodate for relearning limits.
Set the UL usage class. The installer must set
the usage class for the operator to function.
See Identifying Gate Operator Category and
Usage Class on page 7.
NOTE: The usage class setting does not
appear on StrongArmPark DC and Crash
products.
The handing determines which way the gate
opens as you view it from the front access
panel. NOTE: StrongArmPark DC is factory
configured for left handing.
Adjust how quickly the barrier arm opens.
Adjust how quickly the barrier arm closes.
Select setting 1 to return the operator to
factory defaults which globally restores all
menu settings back to new operator status.
NOTICE: If factory defaults are restored,
any customized menu settings will need to
be reprogrammed. Before loading factory
defaults, you can save your customized menu
settings using a PC laptop & S.T.A.R.T.
Establishes communication after wiring dual
gate connections between two operators
in Master/Second (Slave) or Sally Port site
configurations.
This menu item appears if the sequenced gate
menu item SG is set at 0 (off).
Display & Menu Options
SDC Wire
Connections
Not applicable
(N/A)
N/A
N/A
N/A
N/A
N/A
Dual Gate COM
(Gate 1) to Dual
Gate COM (Gate 2)
A to A
B to B
MX3650-01 Rev. D