Overview Of The Smart Dc Controller - HySecurity StrongArmPark DC Programming And Operations Manual

With hysecurity smart dc controller mx3650-01 revision d
Hide thumbs Also See for StrongArmPark DC:
Table of Contents

Advertisement

o
vervIeW of tHe
The Smart DC Controller uses LED's to indicate active inputs when AC power is present. For operators that use
only DC power, you can push a button to show the active inputs. This SHOW LEDS button is at the bottom left
corner near the EMERG OPEN input.
On a new operator no active inputs should appear until external accessories and wiring are attached. If any
inputs are active before connecting external wiring, refer to Troubleshooting.
COMMON
TERMINALS
34
MX3650-01 Rev. D
s
dC C
mart
COM
COM
COM
COM
COM
COM
COM
COM
STOP
OPEN
CLOSE
OPEN
P ARTIAL
SENSOR 1
SENSOR 3
EXIT
LOOP
BLOCK
EXIT
IN OBS
LOOP
OUT OBS
LOOP
CENTER
LOOP
SENSOR 2
SENSOR
COM
+ 24 V
EMERG
OPEN
SHOW
LEDs
Smart DC Controller Board
StrongArmPark DC Programming & Operations
ontroller
Mul�-colored LED
indicates power and gate
status.
RS-232
Ethernet
expansion
USB PORT
USER RELAY 2
Solid state
RS-485
COMMUNICATION
© 2017
www.hysecurity.com