The following bullet points highlight how your automated gate system sites can monitor external entrapment
protection using HySecurity gate operators:
Normally Closed (NC) sensors – Before gate movement occurs, the gate operator verifies that the
external entrapment protection sensor is connected and fully functional.
Build Year (BY) – An added menu item distinguishes between pre-2016 manufacturing dates and
UL 325 - 2016 manufacturing dates. Build Year (BY) is a factory-setting. Build Year 2 (BY 2) is the default for
all HySecurity gate operators indicating a manufacturing date of 2016 in the serial number. Replacement
controller boards for existing sites allow for a Build Year setting of 1 (BY 1) (pre-2016).
Independent Sensor Inputs – The edge, photo eye and photo eye COM inputs on the Smart Touch and
Smart DC Controllers (STC and SDC) have been re-labeled. The same wiring connections become three
independent methods for easy entrapment protection sensor configuration and normally closed outputs.
Table 1: HySecurity Gate Operators requiring External Monitored Entrapment
Protection Sensors
HySecurity Gate Operators
(includes Modular, Correctional, and
UPS models)
SlideDriver 15, 40, 30F, 50VF 2/3, 80, 200
SlideDriver 50VF series
SlideSmart DC 15 & DCS 15
SlideSmart DC 10F & DCS 10F
SwingRiser 14, 14-Twin, 19,
19-Twin, 30, 30-Twin
SwingSmart DC 20 & DCS 20
HydraSwing 40, 40F, 40-Twin, 40F-Twin,
80F, 150
HydraLift 10, 10F, 20, 20F
Table 2: HySecurity Gate Operators maintaining Object Detection
Table 2 indicates those HySecurity gate operators that may be within the exception parameters of UL 325 or
comply with standards other than UL 325, but continue to maintain object detection capabilities. HySecurity
strongly recommends that you assess every site for entrapment zones and provide the necessary protection to
guard against entrapment.
HySecurity Gate Operator's with
Obstruction Protection (Object Detection)
StrongArm (HTG) 14, 20, 28, 36
StrongArmCRASH (M30/M50)
StrongArmPark DC 10 & DCS 10
StrongArmPark DC 14 & DCS 14
WedgeSmart DC 10 & 10 DCS
WedgeSmart DC 14 & 14 DCS
HydraWedge SM50
8
MX3650-01 Rev. D
g
o
ate
perators
Build Year
UL 325 - 2016
(set at the factory)
2
2
2
2
2
2
2
2
UL 325 - 2016
StrongArmPark DC Programming & Operations
: ul 325 – 2016
UL 325 Entrapment Protection Sensor Monitoring Required
Normally Closed (NC) sensors tested & approved.
Three SENSOR Inputs on Controller.
Build Year (BY) factory-set to UL 325 - 2016.
Build Year
Sensor Inputs automatically set to "NOT USED"
Installer has option to change settings as site design dictates.
2
2
2
2
2
2
Installer Menu configurable.