Installer Menu
3 = 75 second delay
LT 3 (75 SECS)
Loitering Alert
0 = 0s delay
1 = 15s
2 = 45s
4 = 105s
5 = 135s
SA 0
0 = No network
(OFF)
1 to 99 = Network "drop" address
SDC Address
0 = Run mode
ELD0 RUN MODE
Exit Loop Set
1 = Show frequency
2 = Show call level 0-7
3 = Set Frequency
0 = Run mode
ILD0 RUN MODE
In Arm Loop Set
1 = Show frequency
2 = Show call level 0-7
3 = Set Frequency
0 = Run mode
OLD0 RUN MODE
Out Arm Loop Set
1 = Show frequency
2 = Show call level 0-7
3 = Set Frequency

0 = Run mode
CLD0 RUN MODE
1 = Show frequency
Center Loop Set
2 = Show call level 0-7
3 = Set Frequency
www.hysecurity.com
© 2017
Table 4: Installer Menu
Setting Options
Display & Menu Options
Menu Tasks & Explanations
This menu item only appears if the #13 User
Relay function has been selected. It adjusts
the time delay before activation of the User
Relay.
Sets the system address for network
communication: 0 = no network
communication
1-99 sets individual poling addresses.
See PD SET PASSWORD in Table 3: User Menu
on page 22.
Controls the Hy5x Free Exit loop detector.
Controls the Hy5x Inside Obstruction Loop
(Inner Arming Loop) detector.
Controls the Hy5x Outside Obstruction Loop
(Outer Arming Loop) detector.
Controls the Hy5x Center Loop detector.
SDC Wire
Connections
User Relay
RS-485. Involves
additional hardware
& software.
Hy5x
Hy5x
Hy5x
Hy5x
MX3650-01 Rev. D
29