HySecurity StrongArmPark DC Programming And Operations Manual page 86

With hysecurity smart dc controller mx3650-01 revision d
Hide thumbs Also See for StrongArmPark DC:
Table of Contents

Advertisement

The two 8Ah batteries are accessible within the operator on a tray next to the gear box.
To replace the batteries, take the following steps:
1. Remove the front access panel.
2. Turn off the DC and AC power switches.
3. Remove the top cover.
4. Access the two 8Ah batteries from the top.
Cut the two black wire ties holding the
batteries to the shelf.
5. Disconnect the red, blue, and black wires
as you lift the batteries through the access
window.
6. To install the two new batteries, reverse
the removal procedure.
• Install the first battery and connect the
black wire.
• Connect the blue jumper wires
between the two batteries.
• Connect the red wire to the red
terminal on the second battery.
7. Replace the top cover.
8. Turn the AC and DC power switches
ON. This cycles power which allows the
operator to search for the target magnet
and "relearn" its limits.
NOTE: Be aware that the arm will cycle open and
close (close or open) as it relearns its limits. If you
don't cycle the power, the operator will not
"relearn" its limits and will not operate properly.
9. Replace the front access panel and lock it.
76
MX3650-01 Rev. D
Cut-away View
Two 8Ah
batteries
Front access
panel
StrongArmPark DC Programming & Operations
Top cover
Black
wire
Red
wire
© 2017
www.hysecurity.com

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents