HySecurity StrongArmPark DC Programming And Operations Manual page 34

With hysecurity smart dc controller mx3650-01 revision d
Hide thumbs Also See for StrongArmPark DC:
Table of Contents

Advertisement

User Menu
US 0
0 = preprogrammed limit
CLEAR COUNT
1 = Clear Transient count
2 = Clear Tenant count
3 = Clear Special count
4 = All User
DS 0 (OFF)
0 = off
1 = detailed
Diagnostic Logs
PD 0 
0 = Off
1 = On, Set Password
Set Password
I
m
nstaller
The Installer Menu options provide more advanced configurations for
the gate operators. Access to the Installer Menu is through the User
Menu. The navigational buttons are the same in both menu modes.
Access:
While a static Run Mode code is being displayed, press the MENU
button twice. (Bypasses the operator status displays.)
When the Close Timer display appears:
1. Access the Installer Menu by simultaneously pressing and
holding the RESET and OPEN buttons.
2. Release both buttons and the Learn Limit display appears. The
LL display is the first item in the Installer Menu.
NOTE: Installer Menu options can also be configured through the use of a
laptop computer and the S.T.A.R.T. software.
Table 4 describes the Installer Menu items and supplies the factory defaults. (Factory settings shown in bold.)
24
MX3650-01 Rev. D
Setting Options
enu
StrongArmPark DC Programming & Operations
Table 3: User Menu
Menu Tasks & Explanations
Clears the logs (counts) of "user types" entering
or exiting through the StrongArmPark DC gate.
This menu is used most often in Parking lot and
revenue control scenarios. Selecting a number and
pressing SELECT again, clears the count.
Set to 0, the SDC logs pertinent operator events
such as faults, errors, or menu manipulation. When
experiencing intermittent problems, set this item
to 1 to record all operator open and close events,
in addition to the normal alert, fault and error logs.
This parameter automatically resets to the default
0 (off) after 24 hours.
To enter a password (up to 80 characters) for
network connectivity, select 1. You can use the
menu navigation buttons to enter the password
(SELECT, NEXT, SELECT). When the password is
set, the display returns to the 0 setting.
NOTE: A System Address (SA) value in the Installer
Menu must be set before the Set Password display
can appear in the User Menu.
SDC Wire Connections
COM
TRANSIENT USER
TENANT USER
SPECIAL USER
USB or RS-232 cable
and laptop computer
loaded with HySecurity
free S.T.A.R.T. software
is required to read the
log file.
Visit www.hysecurity.com
Network: Ethernet or
RS-485
CT 0 (OFF)
CLOSE TIMER
OPEN
CLOSE
STOP
MENU
NEXT
SELECT
PREV
LL 0 (OFF)
LEARN LIMIT
OPEN
CLOSE
STOP
MENU
PREV
NEXT
SELECT
© 2017
www.hysecurity.com
RESET
RESET