Sequenced Gates #2: Loop Layout; Strongarmpark Dc Loop Layout; Mx3650-01 Rev. D Strongarmpark Dc Programming & Operations © 2017 Www.hysecurity.com - HySecurity StrongArmPark DC Programming And Operations Manual

With hysecurity smart dc controller mx3650-01 revision d
Hide thumbs Also See for StrongArmPark DC:
Table of Contents

Advertisement

2
To sequence the gates, set the
Installer Menu item, SG to "2" in
both gate operators.*
Operator & Loops**
As traffic control and security gates
are separated farther apart, Center
Loop moves toward centering under
the Traffic Control Gate.
TRAFFIC CONTROL GATE
*NOTICE
For sequenced gates to operate
properly, all vehicle detectors
must be wired to the Traffic
Control Gate.
If a communication failure occurs,
an AL22 (Alert 22) appears and the
buzzer sounds. The Traffic Control
Gate maintains functionality
whilethe Security Gate defaults
to open until communication is
restored (or the Security Gate is
manually closed).
Drawings not to scale.
52
MX3650-01 Rev. D
s
g
equenCed

StrongArmPark DC Loop Layout

StrongArmPark DC (Traffic Control Gate)
with SlideSmart DC (Security Gate)
OUTER ARMING LOOP
D
(OALD)
(OOLD for Security Gate)
C
C
CENTER LOOP
Loop can be offset from
C/L of barrier arm 1 to 5 ft
(31 to 152 cm)
(IOLD for Security Gate)
A
INNER ARMING LOOP
(IALD)
IALD for Traffic Control Gate or
Free Exit for both operators. If
loop used as Free Exit, you must
have an OALD loop.
FREE EXIT LOOP
(optional)
**NOTICE
Center to center between gates:
4 ft minimum (122 cm)
9 ft maximum (274 cm)
StrongArmPark DC Programming & Operations
#2: l
ates
oop
F
SECURITY SLIDE GATE
Minimum 2 ft (61 cm)
SECURITY SLIDE GATE
Uni- or Bi-directional Traffic Control
E
Vehicles must pass from one loop to
the next without loss of detection.
Dimension "A" = 6 ft minimum to 12 ft
B
maximum (183 to 366 cm).
Dimension "B" = 2 ft minimum to 3 ft
maximum (61 to 91 cm).
Dimension "C" = 3 ft min. to 4 ft max.
Distance from edge of Center Loop to
C/L of the Security Gate is 3 to 4 ft.
Dimension "D" = 6 ft (183 cm).
Dimension "E" =
244 cm)
from C/L of gate: 1 to 5 ft (31 to 152 cm).
Dimension "F" = 10 to 15 feet (3 to 3.6 m)
l
aYout
Optional access control
devices (card reader, etc.).
Align along 6 ft edge of the
Outside Obstruction Loop.
Location changes depending on
uni- or bi-directional traffic.
Minimum 2 ft (61 cm)
4 ft min. to 8 ft (122 to
max. Center Loop can be offset
© 2017
www.hysecurity.com

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents