If standard 11-pin box type vehicle detectors are to be used, perform the following procedure.
If there is sufficient space, install the sockets in the control box; if not, then install them in a separate external
housing. Carefully consider your peripheral connections. Any peripheral device required for safe gate
operation should be attached to 24VDC in case of an AC power outage.
NOTE: Box detectors with relays require five times more power than Hy5x detectors. One Hy5x detector draws about 0.005A.
Consider Hy5x vehicle detectors for DC and Solar powered sites.
1. Connect 24 Volt power to the detector. Connect Pin No. 1 to a 24VAC or 24VDC terminal and Pin No. 2
to common.
2. Connect output Pin No. 6 to the Common Bus and output Pin No. 5 to one of the four detector
terminal inputs (depending upon the detector function required) on the Smart DC Controller.
If multiple detectors are used, route the power wires and common wire from socket to socket (daisy-chaining)
rather than individually running each wire to the same location. The only wires that are separate are the output
wire to the Smart DC Controller and the detector loop input wires.
Always keep the detector loop wires well twisted beyond the area of the loop. The lead in portion sealed in a
saw cut does not need to be twisted so long as the wires are encapsulated in loop sealant and cannot move.
CAUTION
Match detector connection to its
voltage rating (24VAC or 24VDC).
(+24V)
Pin 1
Pin 2
NOTE: Both 24 Volts AC and DC are available, so either detector voltage may be used. 24 VAC is not
available if the Gate Operator is equipped with the UPS option. 24 VAC is available at the spade
terminals on the lower left corner of our power supply (marked ACC); 24 VDC is available from the
Common and the +24 V spade terminals.
48
MX3650-01 Rev. D
11-p
tandard
Loop
Detector
StrongArmPark DC Programming & Operations
B
t
In
ox
Ype
COM
COM
COM
COM
COM
COM
COM
COM
STOP
OPEN
CLOSE
OPEN
P ARTIAL
SENSOR 1
SENSOR 3
EXIT
VEHICLE LOOP
LOOP
BLOCK
EXIT
IN OBS
LOOP
OUT OBS
LOOP
CENTER
LOOP
SENSOR 2
SENSOR
COM
+ 24 V
EMERG
OPEN
To LOOP terminal on Smart
Touch Controller
v
d
eHICle
SHOW
LEDs
© 2017
eteCtors
www.hysecurity.com

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents