eteCtors and tHe
The Smart DC Controller provides an interface for up to four different vehicle detector functions.
NOTE: Standard box type 11 pin (24 VDC or 24 VAC) vehicle detectors may be connected in the traditional manner to the
controller, but HySecurity Hy5B mini-detector modules plug directly into the board, making field installation much faster and
enhancing performance.
The Hy5B detector communicates with the Smart DC Controller microprocessor to achieve the following
benefits:
Automatic Sensitivity – The Hy5B monitors vehicle traffic over the loop and automatically adjusts the
loop sensitivity based on vehicle type and volume.
Automatic Gate Compensation – The Hy5B discerns gate travel over the loop and automatically
compensates for its effect. The compensation allows the Hy5B to operate with a higher sensitivity
which provides better detection capability.
No Loop Crosstalk – Exclusive use of Hy5B vehicle detectors in HySecurity gate operators, completely
eliminates crosstalk and the need to set frequency levels.
Vehicle Counting – Hy5B detects passenger vehicles and motorcycles.
Automatic Lightning Suppression - Where lightning strikes occur often, connecting to the ground
terminal minimizes the chance of activation or lock-up.
Health Scores for Loop – Hy5B monitors the loop for changes that are indicative of possible
problems. A score is accessible through the event log, LG menu item.
Automatic Hy5A emulation mode for backward compatibility.

Hy5B Installation

To install an Hy5B vehicle detector, you will need to take
the following steps:
Test the vehicle loop
To use all the features of Hy5B, update the software
version on the gate operator to the latest version
using S.T.A.R.T. and a PC laptop. Access free
software updates from the HySecurity website:
www.hysecurity.com
Install the Hy5B vehicle detector
Fully cycle the gate at least 2 times to allow the
detector to adjust to the effects of the gate during
travel. Drive a test vehicle over the loops.
44
MX3650-01 Rev. D
s
mart
Hy5B Vehicle Detector – front view
StrongArmPark DC Programming & Operations
dC C
ontroller
Push terminals for
loop wires
Ground terminal for
lightning protection
Optional - Use where
lightning strikes occur.
LED indicator.
Vehicle loop features
and functions explained
on the front label.
Metal pins fit into a socket
on the controller board.