Sequenced Gates #1: Loop Layout; Strongarmpark Dc Loop Layout - HySecurity StrongArmPark DC Programming And Operations Manual

With hysecurity smart dc controller mx3650-01 revision d
Hide thumbs Also See for StrongArmPark DC:
Table of Contents

Advertisement

1
To sequence the gates, set the
Installer Menu item, SG to "1" in
both gate operators.*
Operator & Loops**
As traffic control and security gates
are separated farther apart, adjust
Center Loop toward centerline of
the Traffic Control Gate.
TRAFFIC CONTROL GATE
*NOTICE
For sequenced gates to operate
properly, all vehicle detectors
must be wired to the Traffic
Control Gate.
If a communication failure occurs,
an AL22 (Alert 22) appears and the
buzzer sounds. The Traffic Control
Gate maintains functionality
whilethe Security Gate defaults
to open until communication is
restored (or the Security Gate is
manually closed).
Drawings not to scale.
www.hysecurity.com
© 2017
s
g
equenCed

StrongArmPark DC Loop Layout

StrongArmPark DC (Traffic Control Gate)
with SlideSmart DC (Security Gate)
OUTER ARMING LOOP
D
(OALD)
(OALD for Traffic Control Gate
Not used by Security Gate)
CENTER LOOP
Loop can be offset from
C/L of barrier arm 1 to 5 ft
(31 to 152 cm)
(OALD for Security Gate)
INNER ARMING LOOP
(IALD)
IALD for Traffic Control Gate.
IOLD for Security Gate. Or, Free Exit
for both operators. If loop used as Free
Exit, you must have an OALD loop.
A
FREE EXIT LOOP
(optional)
**NOTICE
Center to center between gates:
4 ft minimum (122 cm)
9 ft maximum (274 cm)
Vehicle Detector Installation and Loop Layouts
#1: l
ates
oop
F
E
Minimum 2 ft (61 cm)
C
C
Uni- or Bi-directional Traffic Control
Vehicles must pass from one loop to
the next without loss of detection.
Dimension "A" = 6 ft minimum to 12 ft
maximum (183 to 366 cm).
B
Dimension "B" = 2 ft minimum to 3 ft
maximum (61 to 91 cm).
Dimension "C" = 3 ft min. to 4 ft max.
Distance from edge of Center Loop to
C/L of the Security Gate is 3 to 4 ft.
Dimension "D" = 6 ft (183 cm).
Dimension "E" =
244 cm)
from C/L of gate: 1 to 5 ft (31 to 152 cm).
Dimension "F" = 10 to 15 feet (3 to 3.6 m)
l
aYout
Optional access control
devices (card reader, etc.).
Align along 6 ft edge of the
Outside Obstruction Loop.
Location changes depending on
uni- or bi-directional traffic.
4 ft min. to 8 ft (122 to
max. Center Loop can be offset
MX3650-01 Rev. D
51

Hide quick links:

Advertisement

Table of Contents
loading