Connecting Accessory Devices - HySecurity SlideDriver 15 Programming And Operations Manual

Vehicular slide gate operator with smart touch controller
Table of Contents

Advertisement

Connecting Accessory Devices

Sensors, such as gate edges and photoelectric beams, protect against potential entrapment. These external
entrapment protection sensors must be monitored for the gate installation to be in compliance with the 2016
revision to UL 325 Standard of Safety.
NOTE: Always check your local area codes and comply with all regulations.
Other types of accessory connections are shown in the following illustration. All accessories require a minimum
of two connections:
a device input
a Common Bus Terminal (COM)
Power Supply
Board
Two wires
attach to COM.
Configuration
depends on
whether AC or
DC powered.
Access controls
(Ex. Card reader, keypad)
NOTE: See Wiring HySecurity Sensors:
Smart Touch on page 131, for photo eye
and gate edge connections.
74
MX3630-01 Rev. J
Power Connector
DRIVE
POWER
1
STOP BUTTON
2
OPEN BUTTON
3
CLOSE BUTTON
REMOTE OPEN AND
4
RADIO CONTROL
5
OPEN/CLOSE
6
OPEN PARTIAL
INTERLOCK OPEN
7
TIME CLOCK OPEN
8
FREE EXIT DETECTOR
DISABLE EXIT DETECTOR
9
DISABLE CLOSE TIMER
INSIDE OBSTRUCTION
10
VEHICLE DETECTOR
OUTSIDE OBSTRUCTION
11
VEHICLE DETECTOR
SHADOW/RESET
12
VEHICLE DETECTOR
SENSOR 1
14
SENSOR COM
SENSOR COM
15
16
DO NOT USE
SENSOR 2
17
18
DO NOT USE
19
SENSOR 3
20
DO NOT USE
CHARGER
21
AC LOSS
HySecurity
22
LOCK INTERLOCK
MX000585
VERSION
23
S/N
EMERG CLOSE
24
FIRE DEPT OPEN
Smart Touch Controller
LED
LIMIT
DUAL GATE
RADIO OPTIONS
RPM
COM
A
B
COM
OPEN
+24V
SlideDriver/SlideDriver 50VF Series
RS485
FREE EXIT
INSIDE LOOP
COM
NO
OUTSIDE LOOP
STATUS
SHADOW
RESET
CENTER LOOP
+24V
S1
COM
LOOP
Not to Scale
© 2019
www.hysecurity.com

Hide quick links:

Advertisement

Table of Contents
loading