Extended Relay Module Option - HySecurity StrongArmPark DC Programming And Operations Manual

With hysecurity smart dc controller mx3650-01 revision d
Hide thumbs Also See for StrongArmPark DC:
Table of Contents

Advertisement

Relay No.
Device Reset Pulse Output
31
Back Out Pulse Output
32
Inbound Transient/Lot Output
33
Outbound Transient/Lot Output
34
Inbound Tenant Output
35
Outbound Tenant Output
36
Inbound Special Output
37
Outbound Special Output
38
39
Set aside for Factory Use
e
r
xtended
The extended relay module provides 8 numbered mechanical relays. R3,
RELAY 3 LOGIC through R10, RELAY 10 LOGIC can be accessed through
the Installer Menu. Set the number for the relay based on the information
found in Tables 4 or 5. Table 5 is oriented toward revenue control parking
lot applications.
Wire communication cable connections between the DUAL GATE ports,
at the base of the SDC, and the extended-mechanical relay module. See
illustrationOverview of the Smart DC Controller on page 34.
42
MX3650-01 Rev. D
Table 7: Programmable User Relays, Revenue Control Parking Applications
Name
N.O. Input. A 250ms pulse occurs when the Center
Loop is triggered. If a back out occurs, this relay
sends a reset pulse to the access control device or
computer system to invalidate the ticket.
N.O. Input. The relay outputs a 250ms pulse when a
back out has occurred based on the criteria given in
the "Revenue Control Parking Functions."
N.O. Input. The relay outputs a 250ms pulse used to
increment the transient and total vehicle counts.
N.O. Input. The relay outputs a 250ms pulse used to
decrement the transient and total vehicle counts.
N.O. Input. The relay outputs a 250ms pulse and
increments the tenant counter when the Tenant User
input is activated and OALD, then CLD, are tripped
and released. This activity signals a prepaid customer
has entered the facility.
N.O. Input. The relay outputs a 250ms pulse and
decrements the tenant counter when the Tenant
User input is activated and IALD, then CLD, are
tripped and released. This activity signals a prepaid
customer has exited the facility.
N.O. Input. The relay outputs a 250ms pulse and
increments the special counter when the SPECIAL
USER input is activated and OALD, then CLD, are
tripped and released. This activity signals a customer
has entered the facility.
N.O. Input. The relay outputs a 250ms pulse and
decrements the tenant counter when the SPECIAL
USER input is activated and IALD, then CLD, are
tripped and released. This activity signals a customer
has exited the facility.
HySecurity Testing Only
m
elaY
odule
StrongArmPark DC Programming & Operations
Description
o
ptIon
Wire Connection
R1, R3 through R10
R1, R3 through R10
R1, R3 through R10
TRANSIENT USER
R1, R3 through R10
TRANSIENT USER
R1, R3 through R10
TENANT USER
R1, R3 through R10
TENANT USER
R1, R3 through R10
SPECIAL USER
R1, R3 through
R10SPECIAL USER
Do not use