7. When the LED on the Hy5B detector stops flashing red, it begins pulsing green which indicates
initialization is complete
NOTE: If using Hy5A emulation mode, the LED does not flash green, it goes dark. Refer to LED Display Status
on page 46.
8. Press the Reset button. *
When you press Reset, the following occurs:
• Checks Hy5B loop connections and re-tunes Hy5B to prevent crosstalk
• Un-installs memory of vehicle detectors physically removed
• Clears alerts
NOTE: If the Hy5B is unplugged after it is initialized, an alert appears on the display, ALERT 10. If the issue is not
resolved, ERROR 3 appears. When faults of this nature occur, the gate operator functions as if the Hy5B is
triggered.
NOTE: * Best Practice: When "re-tuning" Hy5B vehicle detectors, verify that the loops are clear before pressing the Reset button.
CAUTION
Do not connect Free Exit loop wires to the same Hy5B detector co@ntaining obstruction loop wires (reversing
loops). You cannot combine Free Exit vehicle detection with reversing loop detection. If you attempt to do so,
vehicles crossing over the Free Exit will not be detected.
For more information, refer to the Hy5B User Guide and additional instructional material found online
HySecurity website / Tech
www.hysecurity.com
© 2017
and the detector is
Support.
Push terminals for
loop wire.
Accepts 20 - 14 AWG
Strip length: 10mm
(1/2 to 3/8 inch)
CAUTION
Do not leave excess loop wire
coiled in the control box because
it can generate false calls.
Vehicle Detector Installation and Loop Layouts
ready for
use.
Ground spade
LED
Conduit to gate operator
Houses lead in wire
Loops and Hy5B
Loop
wire*
MX3650-01 Rev. D
47