s
ettIng tHe
As an added security measure and to make sure the barrier
arm closes automatically within a reasonable time frame after
all loops are cleared, you must set the Close Timer.
Status Display
GATE CLOSED
User Menu
CT 0 (OFF)
The Close Timer assigns how many seconds will pass before the operator initiates closure of a fully opened
barrier arm after all open commands and reversing sensor inputs have ceased and loops cleared. Every gate
operator needs to have the close timer set to a specific number of seconds (for example, 5 seconds) unless a
hard-wired closing device is connected to the unit, such as a "hold to close" push button station.
To adjust the time (1 to 99 seconds) it takes before the operator initiates gate closure, take the following steps:
1. At a gate status display, press the MENU button twice. This accesses the User Menu and the Close
Timer display appears.
NOTE: If you want gate personnel to operate the gate with the Hold to Close feature found in some push
button stations, then set the Hold to Close menu item to 1. When the Hold to Close menu item is active
(set to 1), the Close Timer menu item is unavailable.
2. Use the Select, and then Next or Previous buttons to change the number of seconds appearing on the
display.
3. To exit the User Menu, press the MENU button. The gate status appears in the display indicating you
have returned to Run Mode.
32
MX3650-01 Rev. D
C
t
lose
Imer
CT 1 (ON)
CLOSE TIMER
CT 10 (SECS)
CLOSE TIMER
StrongArmPark DC Programming & Operations
CT 15 (SECS)
CLOSE TIMER
OPEN
CLOSE
STOP
PREV
NEXT
SELECT
© 2017
MENU
RESET
www.hysecurity.com