Connecting Accessory Devices - HySecurity StrongArm 14F Programming And Operations Manual

Vehicular barrier gate operator with controller
Table of Contents

Advertisement

No.
Smart Touch
Smart Touch
Terminal
Terminal
UL 325 - 2016
pre-2016
7
Interlock Open/
Interlock
Time Clock
Open/Time
Open LED
Clock Open
LED
13
SENSOR 1
Edge Sensor
14
Sensor COM
Photo Eye
Power
- 24 Volts
Common
15
Sensor COM
Photo Eye
Power
- 24 Volts
Common
16
DO NOT USE
DO NOT USE
17
SENSOR 2
Photo
Eye Open
direction
18
DO NOT USE
DO NOT USE
19
SENSOR 3
Photo
Eye Close
direction
20
DO NOT USE
DO NOT USE
21
Charger AC
Charger AC
Loss
Loss
22
Lock Interlock
Lock Interlock
23
Emergency
Emergency
Close
Close
24
Fire Dept Open
Fire Dept
Open
MX3657-01 Rev. D ©2020
Wire Connections
The default is Interlock Open
(TC 1) but can be configured as
the Time Clock Open
(TC 0) input.
Refer to Installer Menu: Table 6
on page 66.
All devices used for entrapment
protection that require
monitoring must be wired to
SENSOR COM.
Refer to How Software Handles
Monitoring External Entrapment
Protection Sensors on page
37 and Wiring HySecurity
Sensors: Smart Touch on page
121.
Refer to Installer Menu: Table 6
on page 66.
Refer to Installer Menu: Table
6 on page 66 used for Break
Away Switch if BA is set to 1 in
installer menu.
Connection from battery
cabinet.
Refer to user relay option 23.
Activate with +24. Refer to OC
setting in the Installer Menu:
Table 6 on page 66.
Activate with +24. See the
Installer Menu: Table 6 on page
66.
STC Inputs & Wiring
Commonly used for...
When set to TC1, terminal
used for interlocked
gate input. Set to TC0,
this input provides a
connection to a timer to
open (7-day timer).
Connection to external
entrapment protection
sensors. (Example: photo
eyes or gate edges.)
Device common power
Connect external
entrapment protection
sensors to these
terminals. The sensors
energize only when the
gate operator receives a
run command.
Use these terminals to
preserve battery power.
NOTE: For pre-2016
gate operators, inputs
are labeled as Photo
Eye Power and 24 Volts
Common.
Connection to external
entrapment protection
sensors. (Example: photo
eyes or gate edges.)
Connection to external
entrapment protection
sensors. (Example: photo
eyes or gate edges.)
DC battery cabinet
supplied gate operators
only.
Locking mechanisms.
Installer menu enabled
and input +24V to trigger.
Requires constant hold
or supervised input.
Overrides photo eyes,
gates edges & vehicle
detectors.
Enable Installer Menu FO
& input +24V to trigger.
Overrides photo eyes and
gates edges.
hysecurity.com | 800-321-9947
DRIVE
POWER
1
STOP BUTTON
2
OPEN BUTTON
3
CLOSE BUTTON
REMOTE OPEN AND
4
RADIO CONTROL
5
OPEN/CLOSE
6
OPEN PARTIAL
INTERLOCK OPEN
7
TIME CLOCK OPEN
8
FREE EXIT DETECTOR
DISABLE EXIT DETECTOR
9
DISABLE CLOSE TIMER
INSIDE OBSTRUCTION
10
VEHICLE DETECTOR
OUTSIDE OBSTRUCTION
11
VEHICLE DETECTOR
SHADOW/RESET
12
VEHICLE DETECTOR
SENSOR 1
14
SENSOR
COM
15
16
DO NOT USE
17
SENSOR 2
18
DO NOT USE
19
SENSOR 3
20
DO NOT USE
CHARGER
21
AC LOSS
22
LOCK INTERLOCK
23
EMERG CLOSE
24
FIRE DEPT OPEN
Smart Touch Controll
LED
LIMIT
DUAL GATE
RPM
COM
A
B
Tact Button
STC Inputs
79