Revenue Control Parking Applications - HySecurity StrongArmPark DC Programming And Operations Manual

With hysecurity smart dc controller mx3650-01 revision d
Hide thumbs Also See for StrongArmPark DC:
Table of Contents

Advertisement

Relay No.
DC Power Failure output
18
Flasher Relay
19
Free Exit Loop Vehicle Detector
20
output
Inside Obstruction Vehicle Detector
21
output
22
Reset Loop Detector output
23
External Latching Gate Lock Output
24
Gate at Partial Open Position
DC Power Alert
25
Free Vehicle Detector Pulse
26
Not Open (requires AC power)
27
Flasher (requires AC power)
28
r
C
evenue
ontrol
Additional mechanical relay options are shown in Table 5. Any of the options can be configured through the
relays on the Smart DC Controller. If you need additional mechanical relay terminals, an optional extended
relay module with 8 terminals is available from HySecurity.
NOTE: System baud rate: 38,400
Table 7: Programmable User Relays, Revenue Control
Relay No.
Outer Arming Loop Active Output
OALD
29
Inner Arming Loop Active Output
30
IALD
www.hysecurity.com
© 2017
Table 6: Programmable User Relays
Name
DC operators only. The relay activates when the battery power
is very low, but the output ceases when the battery is dead. The
relay is triggered when the battery is less than 20 volts.
Flashes lights once per second. The relay is constantly pulsing
except when the open limit switch is triggered.
* Preferred connection is Relay 2, a solid state relay.
Active when the Free Exit Loop is tripped.
Active when the Inside Obstruction loops is tripped.
Active when the Reset loop detector is tripped.
Not used in the Smart DC Controller.
Active when the partial open position is reached or exceeded.
Deactivates when the software detects a low battery voltage
(below 21VDC, but greater than 18VDC) for a duration of 2
seconds or more. To slow battery drain, accessory power loads
are shed.
Activates when the Exit Loop Detector is tripped and causes a
250mS pulse output to occur.
When AC power is detected, this relay activates when the gate
in NOT on the open limit. If AC power fails, or the gate is on the
open limit, the relay is deactivated.
Controls flashing lights that pulse 500ms per second. The relay
is constantly activating except when the open limit switch is
triggered or AC power fails.
p
arkIng
Table 7: Programmable User Relays, Revenue Control Parking Applications
Name
Input. Interlocks an entry device to prevent
pedestrian use. This output is active whenever the
Outer Arming Loop Detector is tripped. NOTE: If
the Center Loop is tripped before the Outer Arming
Loop (indicating a vehicle is exiting the facility), this
relay will not energize.
If the Center Loop is tripped before the Inner Arming
Loop (indicating a vehicle is entering the facility), this
relay will not energize.
Description
a
pplICatIons
Description
SDC Inputs & Wiring
Wire
Connection
Relay 1
Relay 1 or 2*
Relay 1
Relay 1
Relay 1
Relay 1
Relay 1
Relay 1
Relay 1
Relay 1
Relay 1
Wire Connection
R1, R3 through R10
R1, R3 through R10
MX3650-01 Rev. D
41

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents